全文获取类型
收费全文 | 171篇 |
免费 | 3篇 |
国内免费 | 15篇 |
专业分类
化学 | 181篇 |
综合类 | 2篇 |
物理学 | 6篇 |
出版年
2022年 | 7篇 |
2020年 | 6篇 |
2019年 | 4篇 |
2018年 | 5篇 |
2017年 | 9篇 |
2016年 | 8篇 |
2015年 | 7篇 |
2014年 | 10篇 |
2013年 | 22篇 |
2012年 | 12篇 |
2011年 | 9篇 |
2010年 | 11篇 |
2009年 | 8篇 |
2008年 | 4篇 |
2007年 | 10篇 |
2006年 | 5篇 |
2005年 | 11篇 |
2004年 | 12篇 |
2002年 | 6篇 |
2001年 | 2篇 |
2000年 | 3篇 |
1999年 | 2篇 |
1998年 | 1篇 |
1997年 | 3篇 |
1996年 | 2篇 |
1995年 | 3篇 |
1994年 | 4篇 |
1993年 | 1篇 |
1989年 | 1篇 |
1988年 | 1篇 |
排序方式: 共有189条查询结果,搜索用时 78 毫秒
1.
V. I. Dostovalova L. A. Fedorov Y. Knuutinen E. Kolehmainen J. Paasivirta 《Russian Chemical Bulletin》1994,43(4):566-573
A two-particle system of OY-Cl and OY-Br mixed increments for predicting13C NMR chemical shifts of polyhalogenated polyoxybenzenes has been developed. It has been found that only theortho- and para-interactions of the OY and Hal substituents contribute significantly to the13C chemical shifts and that theortho-effects of the OY located between Ha1 and H and those of the OY located between two Ha1 atoms are different. Additional effects are due to solvating solvents. The increment scheme is predictive over the whole class of compounds under consideration and may be realized on personal computers.Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 4, pp. 617–624, April, 1994. 相似文献
2.
J. Díaz-Ferrero M.C. Rodríguez-Larena L. Comellas B. Jiménez 《Trends in analytical chemistry : TRAC》1997,16(10):1865-573
The usual methods for determining polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF) and polychlorinated biphenyls (PCB) are generally expensive and time consuming. This fact has favored the development of faster and cheaper techniques, based on immunoassays and bioassays. This paper reviews these bioanalytical methods and their analytical importance at the present moment. 相似文献
3.
Focant JF Reiner EJ Macpherson K Kolic T Sjödin A Patterson DG Reese SL Dorman FL Cochran J 《Talanta》2004,63(5):1231-1240
Comprehensive two-dimensional gas chromatography with isotope-dilution time-of-flight mass spectrometry (GC × GC-IDTOFMS) was used to measure polychlorinated dibenzo-p-dioxin (PCDD), polychlorinated dibenzofuran (PCDF), and coplanar polychlorinated biphenyl (cPCB) concentrations in ash, sediment, vegetation, and fish samples. The GC × GC capability was achieved by using a quad jet, dual stage, thermal modulator. Zone compression of the GC peaks from modulation resulted in a significant increase of the signal intensity over classical GC-IDTOFMS. The GC × GC column set used an Rtx-Dioxin 2 phase as the first dimension (1D) and an Rtx-500 as the second dimension (2D). The chromatographic separation of the 17 PCDD/Fs and the 4 cPCBs was attained in 1D except for 2,3,7,8-TCDD and CB126 for which deconvoluted ion currents (DIC) were required to be reported separately. The Rtx-500 phase separated the bulk matrix interfering compounds from the target analytes in 2D. The instrumental limit of detection (iLODs) was 0.5 pg for 2,3,7,8-TCDD. The calibration curves showed good correlation coefficients for all the compounds investigated in the concentration range of 0.5–200 pg. GC × GC-IDTOFMS results compared favorably to those from conventional isotope-dilution one-dimensional gas chromatography-high resolution mass spectrometry (GC-IDHRMS). The comprehensive mass analysis of the TOFMS further permitted the identification of other contaminants of concern in the samples. 相似文献
4.
建立了加速溶剂萃取同步净化-同位素内标-气相色谱-高分辨质谱同时测定水产品中32种多氯联苯含量的方法。通过在加速溶剂萃取仪中加入2 g无水硫酸钠、1 g弗罗里硅土、50 g中性氧化铝作为吸附剂实现同步净化的效果,萃取溶剂为二氯甲烷-正己烷(1:1,v/v),萃取温度为100℃,循环2次。萃取结束后分别用0.5 mL浓硫酸净化两次,净化液浓缩定容后,采用气相色谱-高分辨质谱测定,同位素内标法定量。32种多氯联苯在0.1~20 μg/L范围内平均相对响应因子(RRF)的相对标准偏差(RSD)值(n=7)均小于15%,定量限(S/N=10)为0.3~1.9 ng/kg。在草鱼和海鲈鱼空白基质中做加标回收试验,添加水平为5、20和50 ng/kg,得到的平均回收率为71.9%~119.0%(n=6),RSD为3.5%~19.6%。该方法背景干扰低,灵敏度高,重现性好,回收率稳定,适用于水产品中多氯联苯的检测。 相似文献
5.
Ľ. Halušcarka Š. Baláž K. Dercová E. Benická J. Krupčík P. Bielek 《International journal of environmental analytical chemistry》2013,93(1-4):327-336
Abstract The anaerobic degradation of PCB in loamy and clayey soils containing indigeneous microflora was studied. The anaerobic conditions were created by an argon atmosphere in the flasks containing soil flooded by a liquid medium with glucose. GC-ECD analysis of soil extracts after 40 day incubation showed, in addition to the concentration changes of the less chlorinated PCB congeners, a significant decrease in the concentration of highly chlorinated congeners in both soils. The results indicate that in both soil types reductive dehalogenation of PCB congeners was encountered. 相似文献
6.
M. Paleologou W. C. Purdy S. K. Misra S. Z. Korczak 《International journal of environmental analytical chemistry》2013,93(4):215-242
Abstract A novel reaction for the dechlorination of polychlorinated biphenyls (PCBs) as well as most other chlorinated aromatic and aliphatic compounds is evaluated and discussed in terms of its potential for analytical purposes. The active dechlorinating agent is prepared through the reaction of molten sodium or potassium with polyethylene glycols (MW >200), in the absence of oxygen, to form the corresponding alkali metal glycolate, a powerful nucleophilic agent. Special emphasis is given to the mechanistic aspects of the reaction and their importance in terms of achieving high and reproducible yields with analytical quantities of substrate, in short periods of time. The contribution of the techniques: ESR, NMR, IR, UV, MS, GC-ECD, LC-EC, CIDNP-NMR, conductimetry and chloride analysis (amperometric) in elucidating the reaction mechanism and providing valuable kinetic data is illustrated. This reaction can potentially be applied to the determination of PCBs in waste oils. 相似文献
7.
Georgina Fortuny Laura Pineda Antoni Rúbies Francesc Centrich Ramon Companyó 《International journal of environmental analytical chemistry》2013,93(7):707-726
A method for determination of 61 organic pollutants (polycyclic aromatic hydrocarbons and organochlorine, organophosphorous and organonitrogen pesticides) is proposed. It is based on solid phase extraction (SPE) and subsequent analysis of the extract by liquid and gas chromatography coupled to tandem mass spectrometry. Method validation yielded to the following values: limits of quantification, from 0.005 to 0.020?µg?L?1; trueness, 95% to 113% and reproducibility (as percent relative standard deviation), 2% to 15%. Additionally, the method performed well in various proficiency tests. 相似文献
8.
我国水产品中多氯联苯(PCBs)的检测方法,主要以6种指示性PCBs和12种二噁英类共平面PCBs为主,仅涵盖有限的PCBs。为更全面地获得生物体中PCBs的浓度水平,深入探讨PCBs在生物体内的代谢和富集特征,进而准确评价PCBs对人类的暴露水平及风险,以鱼和贝类作为生物样品代表,建立了加速溶剂提取-同位素稀释-高分辨气相色谱-高分辨质谱(ASE-ID-HRGC-HRMS)测定生物样品中82种PCBs的方法。比较了振荡提取和加速溶剂提取两种提取方式的回收率和重复性,最终采用正己烷-二氯甲烷(1∶1, v/v)对PCBs进行加速溶剂提取。考察了各流分淋洗液对PCBs的回收率,确定了样品提取液经8 g 44%酸性硅胶层析柱(内径15 mm), 90 mL正己烷洗脱的净化方式。样品提取液净化浓缩后进行HRGC-HRMS分析,色谱柱采用DB-5MS超低流失石英毛细管柱(60 m×0.25 mm×0.25 μm)。通过优化后的升温程序对化合物进行分离,以保留时间和两个特征离子精准定性,采用同位素内标法定量。结果表明,在0.1~200 μg/L范围内,平均相对响应因子(RRF)的相对标准偏差值(RSD, n=7)均≤20%,相关系数(r2)>0.99。生物样品中PCBs的方法检出限为0.02~3 pg/g;鱼类中PCBs平均加标回收率为71.3%~141%, RSD(n=7)为2.1%~14%;贝类中PCBs平均加标回收率为76.9%~143%, RSD为1.4%~11%。该方法灵敏、准确、可靠,可以更加全面具体地分析鱼和贝类等水产品受PCBs的污染情况,为国内外开展生物监测提供有效的技术支持,从而服务于相关生态环境管理及履行《斯德哥尔摩公约》。 相似文献
9.
有机氯农药(OCPs)和多氯联苯(PCBs)是两类重要的持久性有机污染物,可在环境介质中长期存在,并通过多种途径进入人体,导致人体的高暴露风险。OCPs和PCBs对人体存在诸多健康危害,精准定量人体内OCPs和PCBs的暴露水平是健康效应评价的关键。该研究基于固相萃取-气相色谱-串联质谱联用技术(SPE-GC-MS/MS)建立了同时检测100 μL血清中35种OCPs和PCBs的分析方法。血清样品经尿素沉淀蛋白后,采用Oasis® HLB小柱净化,正己烷-二氯甲烷混合溶液(1∶1, v/v)洗脱,氮吹近干,正己烷定容,多反应监测(MRM)模式检测,内标法定量分析。结果表明,OCPs和PCBs在0.05~50.0 ng/mL范围内线性关系良好,检出限在1.2~71.4 ng/L之间。35种目标分析物的加标回收率在72.6%~142%之间,相对标准偏差小于25%。利用所建立的方法检测了武汉市普通人群血清样本中OCPs和PCBs的浓度水平,结果表明武汉市普通人群广泛暴露于OCPs和PCBs,且以OCPs为主。有8种OCPs和7种PCBs检出率高于50%,其中p,p'-滴滴伊、p,p'-滴滴滴和甲氧滴滴涕检出率达100%,非类二噁英PCBs是PCBs的主要成分。血清中OCPs浓度随年龄增长呈升高趋势,在60岁以上存在性别差异;不同性别、年龄人群血清中PCBs浓度无统计学差异。该方法样本用量少,操作简便,具有较高的准确度和精密度,适用于环境健康研究中大量人群血清样本中痕量OCPs和PCBs的生物监测。 相似文献
10.
气相色谱-质谱法同时测定地下水中42种半挥发性有机污染物 总被引:1,自引:0,他引:1
建立了同时测定地下水中多环芳烃(PAHs)、多氯联苯(PCBs)、有机氯农药(OCPs)和有机磷农药(OPPs)等42种半挥发性有机污染物的分析方法,对固相萃取、液-液萃取、萃取溶剂和色谱柱等分析条件进行优化。最终采用乙酸乙酯-正己烷(1∶4)液液萃取,DB-5MS色谱柱分离,GC-MS/SIM测定,内标法定量。结果表明,42种目标物在0.5~1 000μg/L范围内线性关系良好(r20.995);方法检出限为0.05~3.08 ng/L。在10、40、400 ng/L加标水平下,42种目标物的基体加标平均回收率为73.0%~107%,相对标准偏差(RSD,n=5)为1.4%~11.3%。将方法应用于石家庄周边地区水样检测,结果可靠。该方法灵敏、准确、简单易行,可显著提高地下水中主要有机污染物的分析效率。 相似文献